6.6. Draining Air from the Oil Tubes
To be sure that the oil is optimally applied onto the lane, it
is necessary to make sure no air bubbles are visible in the two
transparent pieces of tube connected to the spray nozzles. If air
bubbles are visible (or worse: there is no oil at all in the
tubes), the air must be let out. This can be done as follows:
- Position the unit on a bowling lane (see 'Mounting the
Unit onto a Bowling Lane').
- Make sure the start indicator
within the start button
burns continuously.
(If this is not the case, go to 'TROUBLE CHECKS').
- Press the illuminated green start button
. The air pump will be
switched on and after a few seconds the unit will start
moving. The start indicator
will flash.
- As soon as the unit starts moving, briefly press the
start button
to temporarily halt the conditioning session; the air
pump will stay on.
- For the left spray nozzle, turn open the shut-off plug at
the top of the nozzle. The oil should now pour out. If
the air bubbles do not move, turn the plug open further.
- If the air bubbles have disappeared, wait another 10
seconds before tightening the shut-off plug; this is to
ensure there is no more air left in the nozzle.
- Repeat items 5 and 6 for the right spray nozzle.
- The drained oil can be re-used provided it is not
polluted.