6.7. Replacing Oil by a New Type
If you want to switch over to a new type of oil, you will have
to drain the current oil from the system. If you do not drain it,
the current oil will mix with the new oil.
- Position the unit on a bowling lane (see 'Mounting the
Unit onto a Bowling Lane').
- Make sure the start indicator
within the start button
burns continuously.
(If this is not the case, go to 'TROUBLE CHECKS').
- Press the illuminated green start button
. The air pump will be
switched on and after a few seconds the unit will start
moving. The start indicator
will flash.
- As soon as the unit starts moving, briefly press the
start button
to temporarily halt the conditioning session; the air
pump will stay on.
- From the left spray nozzle, disconnect the transparent
tube. To do this, push the tube into the fastener on the
nozzle, hold back the quick-disconnect ring, then pull
back the tube out of the fastener.
- The oil will now pour out of the tube under slight
pressure. Wait until no more fluid comes out.
- Connect the tube back to the nozzle. Press the tube
firmly into the fastener, then pull it back to secure the
connection.
- Repeat items 5, 6 and 7 for the right spray nozzle.
- Fill the oil tank with at the most two liters (0.4
gallon) of the new oil (see also 'Supplying Oil' on page
11).
- The air in the oil tubes must now be thoroughly drained.
This is described in 'Draining Air from the Oil Tubes'.